🚚 Free Worldwide Shipping on All Orders!Shop Now
Honeywell Q314A3547 Pilot Burner
HomeStore

Honeywell Q314A3547 Pilot Burner

Honeywell Q314A3547 Pilot Burner

The Honeywell Q314A3547 Pilot Burner is a critical replacement component for residential and light-commercial standing pilot gas systems. This non-primary aerated, target-style assembly is specifically engineered for main burner ignition in natural gas applications. It features a single tip style with a left-hand flame orientation and a pre-installed 0.018-inch BCR-18 insert orifice to ensure precise gas flow and flame stability. The unit is designed with a standard Type A mounting bracket for secure positioning on the main burner, providing reliable ignition performance even in demanding environments. Utilizing a 1/4-inch compression fitting, the Q314A3547 is fully compatible with standard pilot tubing and is built to work seamlessly with Honeywell Q309, Q340, and Q390 thermocouples or Q313 thermopiles. Technicians should note that the Honeywell Q314A3547/U is a direct, identical equivalent. Focus on maintaining the correct 3/8" to 1/2" flame envelope over the thermocouple tip for optimal safety circuit continuity and system uptime.

Key Benefits
  • Broad Compatibility: Functions with Q309, Q340, and Q390 thermocouples or Q313 thermopiles for versatile application across various furnace and boiler models.
  • Precision Engineering: The 0.018" (BCR-18) insert orifice and non-primary aeration design provide a consistent, stable pilot flame for reliable ignition.
  • Ease of Installation: Features a universal "Type A" mounting bracket and standard 1/4" compression fittings, reducing downtime during field replacements.
  • Simplified Inventory: This unit is identical to Honeywell Q314A3547/U, allowing for direct replacement of older or SKU-specific versions.
Common Questions

Is this pilot burner compatible with LP gas conversions?
While this model comes with a 0.018" orifice for natural gas, it features interchangeable, color-coded orifices. To convert to LP gas, a separate BBR-10 (0.010") orifice must be installed to ensure the correct BTU rating and safe operation.

What should I check if the pilot flame keeps lifting or blowing out?
Ensure the non-primary aerated inlet is free from dust and debris. Check that the "Type A" bracket is securely mounted to the main burner; shifting can cause improper target alignment, leading to flame instability during the main burner ignition cycle.

Does this unit include the compression nut and sleeve?
This product typically includes the pilot burner assembly and the insert orifice. When replacing these units, it is professional best practice to use a new 1/4" compression fitting to prevent gas leaks at the pilot tubing connection.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$17.84

Original: $50.98

-65%
Honeywell Q314A3547 Pilot Burner

$50.98

$17.84

Honeywell Q314A3547 Pilot Burner

The Honeywell Q314A3547 Pilot Burner is a critical replacement component for residential and light-commercial standing pilot gas systems. This non-primary aerated, target-style assembly is specifically engineered for main burner ignition in natural gas applications. It features a single tip style with a left-hand flame orientation and a pre-installed 0.018-inch BCR-18 insert orifice to ensure precise gas flow and flame stability. The unit is designed with a standard Type A mounting bracket for secure positioning on the main burner, providing reliable ignition performance even in demanding environments. Utilizing a 1/4-inch compression fitting, the Q314A3547 is fully compatible with standard pilot tubing and is built to work seamlessly with Honeywell Q309, Q340, and Q390 thermocouples or Q313 thermopiles. Technicians should note that the Honeywell Q314A3547/U is a direct, identical equivalent. Focus on maintaining the correct 3/8" to 1/2" flame envelope over the thermocouple tip for optimal safety circuit continuity and system uptime.

Key Benefits
  • Broad Compatibility: Functions with Q309, Q340, and Q390 thermocouples or Q313 thermopiles for versatile application across various furnace and boiler models.
  • Precision Engineering: The 0.018" (BCR-18) insert orifice and non-primary aeration design provide a consistent, stable pilot flame for reliable ignition.
  • Ease of Installation: Features a universal "Type A" mounting bracket and standard 1/4" compression fittings, reducing downtime during field replacements.
  • Simplified Inventory: This unit is identical to Honeywell Q314A3547/U, allowing for direct replacement of older or SKU-specific versions.
Common Questions

Is this pilot burner compatible with LP gas conversions?
While this model comes with a 0.018" orifice for natural gas, it features interchangeable, color-coded orifices. To convert to LP gas, a separate BBR-10 (0.010") orifice must be installed to ensure the correct BTU rating and safe operation.

What should I check if the pilot flame keeps lifting or blowing out?
Ensure the non-primary aerated inlet is free from dust and debris. Check that the "Type A" bracket is securely mounted to the main burner; shifting can cause improper target alignment, leading to flame instability during the main burner ignition cycle.

Does this unit include the compression nut and sleeve?
This product typically includes the pilot burner assembly and the insert orifice. When replacing these units, it is professional best practice to use a new 1/4" compression fitting to prevent gas leaks at the pilot tubing connection.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Product Information

Shipping & Returns

Description

The Honeywell Q314A3547 Pilot Burner is a critical replacement component for residential and light-commercial standing pilot gas systems. This non-primary aerated, target-style assembly is specifically engineered for main burner ignition in natural gas applications. It features a single tip style with a left-hand flame orientation and a pre-installed 0.018-inch BCR-18 insert orifice to ensure precise gas flow and flame stability. The unit is designed with a standard Type A mounting bracket for secure positioning on the main burner, providing reliable ignition performance even in demanding environments. Utilizing a 1/4-inch compression fitting, the Q314A3547 is fully compatible with standard pilot tubing and is built to work seamlessly with Honeywell Q309, Q340, and Q390 thermocouples or Q313 thermopiles. Technicians should note that the Honeywell Q314A3547/U is a direct, identical equivalent. Focus on maintaining the correct 3/8" to 1/2" flame envelope over the thermocouple tip for optimal safety circuit continuity and system uptime.

Key Benefits
  • Broad Compatibility: Functions with Q309, Q340, and Q390 thermocouples or Q313 thermopiles for versatile application across various furnace and boiler models.
  • Precision Engineering: The 0.018" (BCR-18) insert orifice and non-primary aeration design provide a consistent, stable pilot flame for reliable ignition.
  • Ease of Installation: Features a universal "Type A" mounting bracket and standard 1/4" compression fittings, reducing downtime during field replacements.
  • Simplified Inventory: This unit is identical to Honeywell Q314A3547/U, allowing for direct replacement of older or SKU-specific versions.
Common Questions

Is this pilot burner compatible with LP gas conversions?
While this model comes with a 0.018" orifice for natural gas, it features interchangeable, color-coded orifices. To convert to LP gas, a separate BBR-10 (0.010") orifice must be installed to ensure the correct BTU rating and safe operation.

What should I check if the pilot flame keeps lifting or blowing out?
Ensure the non-primary aerated inlet is free from dust and debris. Check that the "Type A" bracket is securely mounted to the main burner; shifting can cause improper target alignment, leading to flame instability during the main burner ignition cycle.

Does this unit include the compression nut and sleeve?
This product typically includes the pilot burner assembly and the insert orifice. When replacing these units, it is professional best practice to use a new 1/4" compression fitting to prevent gas leaks at the pilot tubing connection.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.